Independent Australian plant & equipment hire directoryEarthmoving · Cranes · Access · Compaction · Transport
PW-07 / EQUIPMENT GUIDE

Generator Hire Australia

Portable, towable and containerised generators, lighting towers, distribution boards and temporary power for sites and events.

19 listed suppliers5 machine classesUpdated 2026-09-18
Quick answer

Temporary power keeps sites, events, shutdowns and emergency responses running. Sizing a generator starts with a list of loads: continuous kilowatts, motor starting currents, single or three-phase supply and how many hours it must run.

Motors, welders, compressors and pumps draw several times their running current on start-up, so a generator sized only to running load can trip or stall. Suppliers normally size in kVA and allow headroom for starting loads and future additions.

Remote and long-duration hires need a refuelling plan, bunded fuel storage and a service schedule. Lighting towers, cable, distribution boards and RCD protection are often part of the same package.

Power classes and sizes

The table below lists the classes of generators most commonly available for hire in Australia. Exact specifications vary by make and model—confirm dimensions, weight and capacity with the supplier before booking.

Generator hire classes
ClassSize / specTypical jobs
Portable generator2–8 kVAHand tools, small sites, trades
Towable generator20–150 kVASite sheds, pumps, cranes, events
Large / containerised200–1,000 kVA +Shutdowns, mines, backup for buildings
Lighting tower4 × LED · 9 m mastNight works, roads, security
Distribution / cableBoards, RCDs, leadsSafe temporary power distribution

How to choose the right machine

List every load

Record the running kW and phase of each item and identify motors with high starting current. Share the list with the supplier.

Plan fuel

Ask about fuel consumption at expected load, tank run time, bunding and who refuels.

Consider noise

Residential, hospital and event sites may need super-silenced sets or specific placement.

Get it connected properly

Connection to fixed installations must be done by a licensed electrician with correct changeover and earthing.

Licences, tickets and compliance

  • Temporary electrical installations on construction sites must meet AS/NZS 3012, including RCD protection and regular testing and tagging.
  • Connection to a building's switchboard requires a licensed electrician and correct changeover arrangements.
  • Fuel storage requires bunding appropriate to volume and environmental conditions.

See our plant licences and tickets guide for the full list of High Risk Work Licence classes.

What drives the cost

The hire rate is only part of the total. On short hires these items often add 20–50% to the bill—ask every supplier to quote them the same way:

  • Unit size and run time
  • Fuel and refuelling service
  • Cabling, boards and electrician connection
  • Transport and crane off-load for large sets
  • Standby and backup units for critical loads

For indicative 2026 rates, see the plant hire cost guide.

FAQ

Generator hire FAQ

What size generator do I need?

Add up running loads, allow for motor starting currents and add headroom. A supplier can size it from a load list; many small sites need 20–60 kVA.

Can I plug a generator into my switchboard?

Only via a correctly installed changeover switch, connected by a licensed electrician.

Does generator hire include fuel?

Usually not. Most suppliers deliver full and charge for refuelling or return with a refuel charge.

Turn the job into a clear hire brief.

Suppliers answer faster and quote more accurately when they get the outcome, access, ground and dates up front.